Power System Blockset    
Parallel RLC Load

Implement a linear parallel RLC load.

Library

Elements

Description

The Parallel RLC Load block implements a linear load as a parallel combination of RLC elements. At the specified frequency, the load will exhibit a constant impedance and its power will be proportional to the square of the applied voltage.

Only elements associated with nonzero powers will be displayed in the block icon.

Dialog Box and Parameters

    Nominal voltage Vn
The nominal voltage of the load, in volts rms (Vrms).
Nominal frequency fn
The nominal frequency, in hertz (Hz).
Active power P
The active power of the load, in watts.
Inductive reactive power QL
The inductive reactive power QL, in vars. Specify a positive value, or zero.
Capacitive reactive power QC
The capacitive reactive power QC, in vars. Specify a positive value, or zero.
Measurements
Select Branch voltage to measure the voltage across the Parallel RLC Load block terminals.
Select Branch current to measure the current flowing through the Parallel RLC Load block.
Select Branch voltage and current to measure the voltage and the current of the Parallel RLC Load block.
Place a Multimeter block in your model to display the selected measurements during the simulation. In the Available Measurement listbox of the Multimeter block, the measurement will be identified by a label followed by the block name.

Measurement

Label

Branch voltage

ub:

Branch current

ib:

Example

The following circuit is using a parallel RLC load block to implement a load. This example is available in the psbparalload.mdl file.

See Also
Parallel RLC Branch, Series RLC Load, Series RLC Branch


 Parallel RLC Branch Permanent Magnet Synchronous Machine