xPC Target    

PXI-6070E Digital Input

Scaling Input to Output

Hardware Input
Block Output Data Type
Scaling
TTL
double
TTL low = 0.0
TTL high = 1.0

Driver Block Parameters

Channel Vector - Enter numbers between 1 and 8 to select the digital input lines used with this port. This driver allows the selection of individual digital input lines in any order. The number of elements defines the number of digital lines used.

For example, to use all of the digital inputs for one port, enter

Number the lines beginning with 1 even if the board manufacture starts numbering the lines with 0.

Sampletime - Enter a base sample time or a multiple of the base sample time.

PCI Slot (-1:autosearch) - Enter a number between -1 and n.

If only one board of this type is physically present in the target PC, enter


 PXI-6070E Analog Output (D/A) PXI-6070E Digital Output