xPC Target    

AD 512 Analog Output (D/A)

Scaling Input to Output

Hardware Output
Block Input Data Type
Scaling
volts
double
1

Driver Block Parameters

Channel Vector - This parameter is a combined Channel Vector and Range Vector. The number of elements defines the number of D/A channels used.

Enter a range code for each of the channels used. This driver allows a different range for each channel with a maximum of 2 channels.

The following table is a list of the ranges for this driver and the corresponding range codes.

Input range (V)
Range code
Input range (V)
Range code
-10 to +10
-10
0 - 10
10
-5 to + 5
-5
0 - 5
5

For example, if the first channel is -10 to + 10 volts and the second channel is 0 to +5 volts, enter

Sample Time - Enter the base sample time or a multiple of the base sample time.

BaseAddress - Enter the base address of the board. This entry must correspond to the DIP-switch settings on the board. For example, if the base address is 300 (hexadecimal), enter


 AD 512 Analog Input (A/D) AD 512 Digital Input