xPC Target | ![]() ![]() |
Quartz-MM5 Counter FM & ARM
The Quartz-MM5 has one AM9513A chip with 5 counters.
The Quartz-MM5 FM & ARM driver programs the AM9513A for FM (Frequency Modulation) signal generation (a square wave with fixed duty cycle and variable frequency). Additionally the driver allows to arm and disarm the counter by the second block input.
Scaling Input to Output
Hardware Output |
Block Input Data Type |
Scaling |
TTL |
Variable frequency: double Arm: double |
<0.5 disarmed >0.5 armed |
Driver Block Parameters
Counter. From the list, choose 1, 2, 3, 4, 5, 6, 7, 8, 9, or 10 to select which counter is used with this driver block. In each case, one block is needed for each counter.
Frequency Base - From the list, choose F1=1MHz, F2=100kHz, F3=10kHz, F4=1kHz, or F5=100Hz to set the base frequency. The XTAL frequency is assumed to be 1MHz, therefore the jumper on the CIO-CTR05 has to be in position 1MHz not 5MHz.
Initial Relative Output Frequency - Enter a value between 0 and 1. The Initial Relative Output Frequency defines the initial output frequency of the FM-signal relative to the Frequency Base during driver initialization.
For example, if the initial output frequency of a square wave has to be 17.5 kHz, then choose F2=100kHz as the Frequency Base and enter 0.175
as the Initial Relative Output Frequency. 100kHz x 0.175 = 17.5 kHz
Duty Cycle. Enter a value between 0 and 1 to set the duty cycle. The Duty Cycle is held fixed during simulation.
Initial Toggle State - From the list, choose high or low. The Initial Toggle State sets the initial digital level (high or low) of the output. For example, if the Duty Cycle is 0.25 and the Initial Toggle State is High, the first 25% of the period will have a high level and the last 75% will have a low level.
Initial ARM State - From the list, choose Disarmed or Armed. The Initial ARM State defines if the counter should be armed or disarmed after driver initialization. The ARM State during a simulation can be controlled by the second block input. If a value 0 is asserted, the counter is disarmed. If a value 1 is asserted, the counter gets armed.
Sample Time - Enter the base sample time or a multiple of the base sample time. The sample time indicates the update rate of registration on the input (Duty Cycle)
BaseAddress - Enter the base address of the board. This entry must corresponds to the DIP-switch settings on the board. For example, if the base address is 300 (hexadecimal), enter
0x300
![]() | Quartz-MM5 Counter FM | Quartz-MM5 PWM Capture | ![]() |