Fixed-Point Blockset    
FixPt Gateway In Inherited

Convert a Simulink data type to a Fixed-Point Blockset data type, and inherit the data type and scaling

Description

The FixPt Gateway In Inherited block is a masked S-function that converts a built-in Simulink data type to a Fixed-Point Blockset data type.

The block requires two inputs. The first (top) input provides the data type and scaling information. The second (bottom) input passes through to the output, and inherits the data type and scaling of the first input. If you want to explicitly specify the output data type and scaling, use the FixPt Gateway In block.

The Treat input as parameter list controls how the input is processed. The possible values are Real World Value and Stored Integer. In terms of the general encoding scheme described in Scaling, Real World Value treats the input as V = SQ + B where S is the slope and B is the bias. Stored Integer treats the input as a stored integer, Q. For more information about this parameter list, refer to the FixPt Gateway In block.

For a detailed description of all other block parameters, refer to Block Parameters.

Remarks

Inheriting the data type and scaling provides these advantages:

Parameters and Dialog Box

Treat input as
Treat the input as a real-world value or as an integer.
Round toward
Rounding mode for fixed-point output.
Saturate to max or min when overflows occur
If checked, fixed-point overflows saturate. Otherwise, they wrap.
Override data type(s) with doubles
If checked, the output data type is overridden with doubles.
Log minimums and maximums
If checked, minimum and maximum simulation values are logged to the workspace.

Characteristics

Input Port
Any built-in Simulink data type
Output Port
Any data type supported by the blockset
Direct Feedthrough
Yes
Sample Time
Inherited
Scalar Expansion
No
States
0
Vectorized
Yes


 FixPt Gateway In FixPt Gateway Out