DSP Blockset | ![]() ![]() |
Output ones or zeros for a specified number of sample times.
Library
DSP Sources,
Signal Management / Switches and Counters
Description
The N-Sample Enable block outputs the inactive value (0
or 1
, whichever is not selected in the Active level parameter) during the first N sample times, where N is the Trigger count value. Beginning with output sample N+1, the block outputs the active value (1
or 0
, whichever is selected in the Active level parameter) until a reset event occurs or the simulation terminates.
The Reset input check box enables the Rst
input port. At any time during the count, a trigger event at the input port resets the counter to its initial state. The triggering event is specified by the Trigger type pop-up menu, and can be one of the following:
The output is always sample-based.
Dialog Box
0
or 1
. Tunable.Rst
input port.Rst
port is enabled. Tunable.=
Ts*(N+1).See Also
Counter |
DSP Blockset |
N-Sample Switch |
DSP Blockset |
See Creating Signals Using Signal Generator Blocks for related information.
![]() | Multiport Selector | N-Sample Switch | ![]() |