Specify the time between consecutive scanned hardware channels
Description
ChannelSkew
applies only to scanning hardware and not to simultaneous sample and hold (SS/H) hardware.
For scanning hardware, ChannelSkew
is configurable only when ChannelSkewMode
is set to Manual
. If ChannelSkewMode
is set to Minimum
or Equisample
, then ChannelSkew
is automatically set to the appropriate device-specific read-only value. For SS/H hardware, the only valid ChannelSkew
value is zero. SS/H hardware includes Agilent Technologies devices and sound cards.
The ChannelSkew
value is specified in seconds.
Characteristics
Usage |
AI, Common |
Access |
Read/write (depends on ChannelSkewMode value) |
Data type |
Double |
Read-only when running |
Yes |
Values
For all supported hardware, the default value is zero. For SS/H hardware, the only valid value is zero. For scanning hardware, the value depends on ChannelSkewMode
.